ElecSil™  

Electronic Silicone

 Type : Fabric combined

■ Thickness / Tension : 0.3mm / Up to 400%

■ Conductivity : < 10Ω

■ Washing / Durability : Washable

Electronic Silicone

 Type : Fabric combined

■ Thickness / Tension : 0.3mm / Up to 400%

■ Conductivity : < 10Ω

■ Washing / Durability : Washable


Elecsil A

■ High conductivity: Metal material based

■ Direct printing on the fabric:  Makes the process simple and the   production easy

 Durability: Stays in washing

■ Tension: Stretchable

■ Material of Smart Apparels: used as electrode and wire

■ Strong traction at skin: Works and lasts longer than disposable hydrogel electrodes but thinner than carbon rubber electrodes

Elecsil B

■ Carbon based with acid resistance

■ Skin contact between PDMS and carbon black is harmless to human  body and is commonly used as carbon rubber electrode pad.

■ Comparing to conventional carbon electrode pads, skin contact is excellent due to slim thickness with soft hardness and also skin adhesion.

■ Applied by coating, it reduces skin contact resistance which improves function

VARIOUS ICT-XR APPAREL  

USING CONDCUTIVE ELECTRODES

Elecsil A

■ Easy to wear

■ Durable

■ High conductivity below 10Ω

■ Washable, reusable, skin friendly

■ Competitive price due to raw materials and process. 

Manufacturing process available with usual facility in common facteries

■ ElecSil expected to be involved in various industries, that can be used for ICT, XR (VR, AR, MR), 

medical smart clothing, and daily wearable devices

XR APPAREL 

THAT FEELS VR 

XR Haptic Smart Apparel

Platform that can deliver diverse senses through the development of smart clothing that feels virtual touch in virtual reality (VR / AR / MR). 

Can be connected to various contents such as game, video, commercial, manufacturing, medical and education.

■ Clothing-type electrical stimulation technology through conductive ElecSil
Electrical stimulation of biceps, deltoid muscles, abdomen and back according to tactile sense


■ Temperature control technology of specific parts with flexible Peltier element attached to clothing
Installed in the blue area to feel temperature in VR

■ Detachable wearable device

Device conducts electric stimulation and temperature control according to 

tactile signal in contents


■ Linked technology with application and contents

Product Structure


ELECSIL™ 

AVAILABLE CONTENTS 

 Game


Game : PC/ console game, mobile game, etc.

Theme Park : Roler coaster, 4D Simulator, etc.

 Broadcast


Broadcast : Virtual studio, drama VR contents production, sports broadcast, concert live performance, etc.

Advertising : virtual advertising system, exhibition hall virtual experience, etc.

 Medical


Surgery field : Surgery education, advanced surgery training, etc.

Neuropsychiatry : Virtual Simulation Mental Behavior Therapy

Imaging Diagnostics : CG application including 3D virtual colonoscopy

Rehabilitation Medicine : Simulation training for rehabilitation

Healthcare field : Remote medicine, Remote fitness, etc.

Other field : 3D realization of patient information through sensors such as MRI and CT

 Education


E-Learning : Educational contents such as 

pop-up books

Training : Military Operations Training, Vocational Training

 Manufacturing


Automobile : virtual test, design and design, autonomous driving experience, etc.

Aviation : Virtual training on wiring assembly, painting process, in-flight service, etc.

Miscellaneous : Obtain complex machine assembly, AS information

 Movie


Movie : Tech-Film

Navigation : 3D virtual path, realistic image based realistic navigation

Drones: first person cast (FPV) video, e-sports, etc.

Real estate : virtual model houses, real estate video, etc.

VR HAPTIC GLOVES 

S-IDEA 2018 GRAND PRIZE 

  VR haptic gloves concept design

VRG  / TYPE A / BLACK . WHITE

TYPE A is a design that satisfies the conditions suggested by 

Wave Company. It is a method of wearing the Glove after connecting 

the strap directly to the module part like a smart watch. 

Structure is made so that strap can be replaced easily, and module 

of simple and soft form is constructed. Glove Form is maintained 

by using PU material for easy wearing while securing elasticity 

of material used for VR Glove.

The way the signal and electricity flow is expressed in Blue Color of Wave Company, and the Module and Glove are connected to 4 terminals, and the power and operation buttons are placed on the front of the module, and the USB port is arranged on the rear, and the upper part is LED to the 'Wave Company' parts.

EMS(Electronic Muscle 

Stimulation) APPAREL 

Product Diagram



EMS Apparel

■ Massage biceps, deltoids muscles, abdomen and lumbar back muscles

■ Commercialization ongoing as developing ElecSil™ and EMS electric stimulator

EMS(Electronic Muscle 

Stimulation) NECK PILLOW 

■ Massage effect with electric stimulation on back neck

■ Maximize portability by using mobile phone as the battery

■ Ideal for long trips

■ Minimized skin pain due to electrical stimulation

■ Due to the skin contact impedance of 40% compared to the commercial hydrogel electrode

Skin Contact Impedance Comparison


EMS pillow line-up

EMS Cervical pillow

EMS Cervical pillow

EMS Shoulder pillow

EMS Shoulder pillow

EMS Back pillow

EMS Back pillow

EMS leg pillow

EMS leg pillow

CLOTHING ELECTRODE PERFORMANCE

EVALUATION OF ElecSil™ 

NO.
Subject
Tolerance
1

   10 Hz impedance average of 12 electrode pairs  

    < 2kΩ

   10 Hz impedance average of 12 electrode pairs

    < 3kΩ

2

   DC offset voltage (n=12)

    < 100 mV

3

  Combined offset instability and internal noise   

    < 150 ㎶

4

   Defibrillation overload recovery (polarization potential)

    < 100 mV

   Rate of change of polarization Potential

    < 1mV/sec

   After test, 10Hz electrode impedance

    < 3kΩ

5

   Bias current tolerance

    < 100 mV

Meets all ANSI / AAMI EC12: 2000 standards for ECG disposable hydrogel electrodes.

Reusable ElecSil ™: Disposable electrode performance levels exceed the limits of 

ECG electrode standard ANSI / AAMI EC12: 2000


<ANSI / AAMI EC12 : 2000 Medical Electrode Test Items>

■ Used for medical electrodes

■ Passed 100% of ECG Electrode Specification


SUBSCRIBE.

SIGN UP FOR 10% OFF YOUR FIRST ORDER

    Where’s My Order?

             SIZE & FIT

             SHIPPING & RETURNS

             WARRANTY

             CONTACT US


Company Registration No. 2158744601 / Contacts : +82-4044-7331 / info@wavecompany.net

Copyright © 2019 WaveWear Company., LTD. All Rights Reserved.