ElecSil™  

Electronic Silicone

 Type : Fabric combined

■ Thickness / Tension : 0.3mm / Up to 400%

■ Conductivity : < 10Ω

■ Washing / Durability : Washable

ElecSil™          

Conductive Silicone Rubber

Coated Sports Wear 

 Type : Fabric combined, Stretchable Double Coated Electrode Wear 

■ Electrical Characteristic : Skin contact impedance similar with Hydrogel electrode

■ Applications: Electrical Muscle Stimulation(EMS), Electrotactile(Haptic), ECG measurement etc.

■ Washing / Durability : Washable (using a washing machine, more than 20 times)


Elecsil™A

■ High conductivity: Metal material based

■ Direct printing on the fabric:  Able to makes the process of Screen Printing, based the production facility of WAVE WEAR

 Durability: Stays in washing, able to use longer than disposable electrode(Hydrogel) 

■ Tension: Stretchable, Thin film(~0.3mm) but not ripped


Elecsil™B

■ Carbon based with chemical resistance, acid resistance

■ Coated on Elecsil A

■ Skin harmless : Mainly consisted of PDMS, Carbon black 

■ Excellent contact surface : By adhesion and  Friction on the surface

■ Minimum impedance variation when activating : 

Excellent contact surface + Pressure by apparel 

■  Low Skin Contact Impedance similar with Disposable electrode 

VARIOUS ICT-XR APPAREL 
USING CONDCUTIVE ELECTRODES 

VARIOUS ICT-XR APPAREL  

USING CONDCUTIVE ELECTRODES

■ Easy to wear

■ Focus on Reusable, Skin Contact Impedance And Biocompatibility(Skin Friendly)

■ Production based Screen printing 

■ Various Applications: ICT-Haptic, XR-Haptic, EMS, TENS, Healthcare, ECG, EMG etc.


XR APPAREL 

THAT FEELS VR 

XR APPAREL 
THAT FEELS VR 

XR Haptic Smart Apparel

Platform that can deliver diverse senses through the development of smart clothing that feels virtual touch in virtual reality (VR / AR / MR). 

Can be connected to various contents such as game, video, commercial, manufacturing, medical and education.

■ Clothing-type electrical stimulation technology through conductive ElecSil
Electrical stimulation of biceps, deltoid muscles, abdomen and back according to tactile sense


■ Temperature control technology of specific parts with flexible Peltier element attached to clothing
Installed in the blue area to feel temperature in VR

■ Detachable wearable device

Device conducts electric stimulation and temperature control according to 

tactile signal in contents


■ Linked technology with application and contents

Product Structure


EleSil™ AVAILABLE
CONTENTS  

ELECSIL™

AVAILABLE CONTENTS 

 Game


Game : PC/ console game, mobile game, etc.

Theme Park : Roler coaster, 4D Simulator, etc.

 Broadcast


Broadcast : Virtual studio, drama VR contents production, sports broadcast, concert live performance, etc.

Advertising : virtual advertising system, exhibition hall virtual experience, etc.

 Medical


Surgery field : Surgery education, advanced surgery training, etc.

Neuropsychiatry : Virtual Simulation Mental Behavior Therapy

Imaging Diagnostics : CG application including 3D virtual colonoscopy

Rehabilitation Medicine : Simulation training for rehabilitation

Healthcare field : Remote medicine, Remote fitness, etc.

Other field : 3D realization of patient information through sensors such as MRI and CT

 Education


E-Learning : Educational contents such as 

pop-up books

Training : Military Operations Training, Vocational Training

 Manufacturing


Automobile : virtual test, design and design, autonomous driving experience, etc.

Aviation : Virtual training on wiring assembly, painting process, in-flight service, etc.

Miscellaneous : Obtain complex machine assembly, AS information

 Movie


Movie : Tech-Film

Navigation : 3D virtual path, realistic image based realistic navigation

Drones: first person cast (FPV) video, e-sports, etc.

Real estate : virtual model houses, real estate video, etc.

VR HAPTIC GLOVES
S-IDEA 2018 GRAND PRIZE  

VR HAPTIC GLOVES 

S-IDEA 2018 GRAND PRIZE 

  VR haptic gloves concept design

VRG  / TYPE A / BLACK . WHITE

TYPE A is a design that satisfies the conditions suggested by 

Wave Company. It is a method of wearing the Glove after connecting 

the strap directly to the module part like a smart watch. 

Structure is made so that strap can be replaced easily, and module 

of simple and soft form is constructed. Glove Form is maintained 

by using PU material for easy wearing while securing elasticity 

of material used for VR Glove.

The way the signal and electricity flow is expressed in Blue Color of Wave Company, and the Module and Glove are connected to 4 terminals, and the power and operation buttons are placed on the front of the module, and the USB port is arranged on the rear, and the upper part is LED to the 'Wave Company' parts.

EMS(Electronic 
Muscle Stimulation) APPAREL 

EMS (Electronic Muscle 

Stimulation) APPAREL 

Product Diagram



Shirt with EMS Fuction 

Vest type Inner Wear with EMS Fuction

EMS Apparel

■ Massage biceps, deltoids muscles, abdomen and lumbar back muscles

■ Commercialization ongoing as developing ElecSil™ and EMS electric stimulator

EMS(Electronic 
Muscle Stimulation)

NECK PILLOW 

EMS (Electronic Muscle 

Stimulation) NECK PILLOW 

■ Massage effect with electric stimulation on back neck

■ Maximize portability by using mobile phone as the battery

■ Ideal for long trips

■ Minimized skin pain due to electrical stimulation

■ Due to the skin contact impedance of 40% compared to the commercial hydrogel electrode

Skin Contact Impedance Comparison


EMS pillow line-up

EMS Cervical pillow
EMS Cervical pillow
EMS Shoulder pillow
EMS Shoulder pillow
EMS Back pillow
EMS Back pillow
EMS leg pillow
EMS leg pillow

CLOTHING ELECTRODE PERFORMACE EVALUATION OF ElecSil™  

CLOTHING ELECTRODE PERFORMANCE

EVALUATION OF ElecSil™ 

NO.
Subject
Tolerance
1

   10 Hz impedance average of 12 electrode pairs  

    < 2kΩ

   10 Hz impedance average of 12 electrode pairs

    < 3kΩ

2

   DC offset voltage (n=12)

    < 100 mV

3

  Combined offset instability and internal noise   

    < 150 ㎶

4

   Defibrillation overload recovery (polarization potential)

    < 100 mV

   Rate of change of polarization Potential

    < 1mV/sec

   After test, 10Hz electrode impedance

    < 3kΩ

5

   Bias current tolerance

    < 100 mV

Meets all ANSI / AAMI EC12: 2000 standards for ECG disposable hydrogel electrodes.

Reusable ElecSil ™: Disposable electrode performance levels exceed the limits of 

ECG electrode standard ANSI / AAMI EC12: 2000


<ANSI / AAMI EC12 : 2000 Medical Electrode Test Items>

■ Used for medical electrodes

■ Passed 100% of ECG Electrode Specification



Company Registration No. 2158744601 / Contacts : +82-4044-7331 / info@wavecompany.net 